Solis-(100-110)K-5G

400V: 100K/110K

100-110kW three phase series string inverter adopt 10 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Max. 13A per string, 150% DC overloading capability Remote & local intelligent IV scan function.

cooling

Intelligent Redundant Fan-Cooling Concept

MPPT

10
MPPT Number

RS485

WiFi/GPRS
Real time Monitoring

MPPT Voltage Range

180-1000 V
MPPT Voltage Range

IP66

IP66
Ingress Protection

APP STORE

App Store
IOS/Android

100-110kW Solis Three Phase Inverters

Leading Features

  • 10 MPPTs, max. efficiency 98.7%
  • High power tracking density 90MPPT/MW
  • AFCI protection, proactively reduces fire risk
  • Type I SPD for AC (optional)
  • Night SVG function
  • Remote firmware upgrade with simple operation
  • Support “Y” type connection in DC side
  • 150% DC/AC ratio
  • Compatible with 500W+ bifacial modules
  • Built-in PID recovery for better module performance (optional)
  • Intelligent string monitoring. Smart I-V curve scan
  • Power line communication (PLC) (optional)

Technical Specifications

Solis-100K-5G
Solis-110K-5G

Input DCMax. input voltage:1100 vRated voltage:600 V
Start-up voltage:195 VMPPT voltage range:180-1000 V
Max. input current:10*26 AMax. short circuit current:10*40 A
MPPT number/Max.
input strings number:
10/20
Output ACRated output power:100 kWMax. apparent output power:110 kVA
Max output power:110 kWRated grid voltage:3/N/PE, 220 V / 380 V,
230 V / 400 V
Rated grid frequency:50 Hz / 60 HzRated grid output current:152.0 A / 144.3 A
Max. output current:167.1 APower Factor:>0.99
(0.8 leading - 0.8 lagging)
THDi:<3%DC injection current:<0.5% In
EfficiencyMax. efficiency:98.7%EU efficiency:98.3%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
(AC Type I optional)
Grid monitoring:YesAnti-islanding protection:Yes
Strings monitoring:YesI/V Curve scanning:Yes
Integrated PID recovery:OptionalIntegrated AFCI (DC
arc-fault circuit
protection):
Yes
Integrated DC switch:YesIntegrated AC switch:Optional
General DataDimensions (W*H*D):1065*567*344.5 mmWeight:84 kg
Topology:TransformerlessSelf consumption (night):<2 W
(without anti-PID)
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:IEC 61683, IEC 60068,
IEC 61727, IEC 62116,
EN 50530, IS 16169 /
IS 16221(BIS)
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 185 mm²)
Display:LCDCommunication:RS485, Optional: DLS-W,
DLS-G, PLC

Input DCMax. input voltage:1100 vRated voltage:600 V
Start-up voltage:195 VMPPT voltage range:180-1000 V
Max. input current:10*26 AMax. short circuit current:10*40 A
MPPT number/Max.
input strings number:
10/20
Output ACRated output power:100 kWMax. apparent output power:121 kVA
Max output power:110 kWRated grid voltage:3/N/PE, 220 V / 380 V,
230 V / 400 V
Rated grid frequency:50 Hz / 60 HzRated grid output current:167.1 A / 158.8 A
Max. output current:183.8 APower Factor:>0.99
(0.8 leading - 0.8 lagging)
THDi:<3%DC injection current:<0.5% In
EfficiencyMax. efficiency:98.7%EU efficiency:98.3%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
(AC Type I optional)
Grid monitoring:YesAnti-islanding protection:Yes
Strings monitoring:YesI/V Curve scanning:Yes
Integrated PID recovery:OptionalIntegrated AFCI (DC
arc-fault circuit
protection):
Yes
Integrated DC switch:YesIntegrated AC switch:Optional
General DataDimensions (W*H*D):1065*567*344.5 mmWeight:84 kg
Topology:TransformerlessSelf consumption (night):<2 W
(without anti-PID)
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:IEC 61683, IEC 60068,
IEC 61727, IEC 62116,
EN 50530, IS 16169 /
IS 16221(BIS)
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 185 mm²)
Display:LCDCommunication:RS485, Optional: DLS-W,
DLS-G, PLC

Contact

Request a Quote

We would love to hear from you, Please fill in the short form with your Questions, Suggestions, Feedback, Enquiries. Partner with Fiscap to build better and more efficient projects.