Solis-125K-EHV-5G

125kW three phase series string inverter have Maximum 20 strings input, support 1.5 DC/AC inverter load ratio and higher generation efficiency,Maximum efficiency up to 99.1%.Touch safe DC Fuse holders adds convenience and safety.

THDI

<3%
THDi

MPPT

20 Max Input
Strings Number

RS485

RS485, Optional:,
PLC Real time monitoring

MPPT Voltage Range

860-1450V
MPPT voltage range

IP66

IP65
Ingress protection

APP STORE

App Store
IOS/Android

125kW Solis Three Phase Inverters

Leading Features

  • Max. efficiency 99.1%
  • Compatible with bifacial modules
  • Equipped with AC/DC switch, safe and convenient maintenance
  • Remote firmware upgrade with simple operation
  • Supports aluminum wire access to reduce cost
  • 150% DC/AC ratio
  • Built-in PID recovery for better module performance
  • Multiple communication modes applicable to various scenarios
  • Max. DC input voltage: 1500V

Technical Specifications

Solis-125k-EHV-5G

Input DCMax. input voltage:1500 VRated voltage:950 V
Start-up voltage:900 VMPPT voltage range:860-1450 V
Max. input current:150AMax. short circuit current:300 A
MPPT number/Max.
input strings number:
1/20
Output ACRated output power:125 kW
Max output power:125 kWRated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:120.3A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.1%EU efficiency:98.6%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated AC switch:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1178*713.5*315 mmWeight:84 kg
Topology:TransformerlessSelf consumption (night):<3 W
(without anti-PID)
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP65Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:G98 or G99, EN 50549-1/-2,
IEC61727, IEC62116
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC