• info@fiscap.in
  • B-14, Globus D Complex, Sec. 63, Noida, UP - 201301

Reliablity

Safety

Capacity

Solis-(215-255)K-EHV-5G

215-255kW three phase series string inverter have Maximum 28 strings input, support “Y” type connection in DC side. Maximum string input current 15A, support bifacial modules access. Supports anti-PID function to improve system eff iciency. High-precision intelligent strings monitoring reduces fault location time.

THDI

<3%
THDi

MPPT

9/12/14
MPPT number

RS485

RS485, Optional:,
PLC Real time monitoring

MPPT Voltage Range

480-1500V
MPPT voltage range

IP66

IP66
Ingress protection

APP STORE

App Store
IOS/Android

215-255kW Three Phase Inverters

Leading Features

  • 9/12/14 MPPTs, max. efficiency 99%
  • High power tracking density 60MPPT/MW
  • IP66
  • Fuse free design, safe and maintenance free
  • Night SVG function
  • Remote firmware upgrade with simple operation
  • DC side supports two sinks and one access
  • Reserve DC energy storage access
  • Supports aluminum wire access to reduce cost
  • 150% DC/AC ratio
  • Compatible with 500W+ bifacial modules
  • Built-in PID recovery for better module performance
  • Globally recognised branded component for longer life
  • Intelligent string monitoring. Smart I-V curve scan
  • Power line communication (PLC) (optional)

Technical Specifications

Solis-215K-EHV-5G-PLUS
Solis-250K-EHV-5G
Solis-250K-EHV-5G-PLUS
Solis-255K-EHV-5G
Solis-255K-EHV-5G-PLUS

Input DCMax. input voltage:1500 VRated voltage:1080 V
Start-up voltage:500 VMPPT voltage range:480-1500 V
Max. input current:9*30 AMax. short circuit current:9*50 A
MPPT number/Max.
input strings number:
9/18
Output ACRated output power:215 kVA @ 30°C /
205 kVA @ 40°C /
195 kVA @ 50°C
Rated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:155.2 A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.0%EU efficiency:98.8%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated PID recovery:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1125*770*384 mmWeight:113 kg
Topology:TransformerlessSelf consumption (night):<2 W
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:EN50549, G99,
AS4777.2, VDE0126,
IEC61727, VDE4110,
CEA 2019
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC

Input DCMax. input voltage:1500 VRated voltage:1080 V
Start-up voltage:500 VMPPT voltage range:480-1500 V
Max. input current:14*26 AMax. short circuit current:14*40 A
MPPT number/Max.
input strings number:
14/28
Output ACRated output power:250 kVA @ 30°C /
235 kVA @ 40°C /
220 kVA @ 50°C
Rated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:184.0 A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.0%EU efficiency:98.7%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated PID recovery:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1125*770*384 mmWeight:113 kg
Topology:TransformerlessSelf consumption (night):<2 W
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:EN50549, G99,
AS4777.2, VDE0126,
IEC61727, VDE4110,
CEA 2019
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC

Input DCMax. input voltage:1500 VRated voltage:1080 V
Start-up voltage:500 VMPPT voltage range:480-1500 V
Max. input current:12*30 AMax. short circuit current:12*50 A
MPPT number/Max.
input strings number:
12/24
Output ACRated output power:250 kVA @ 30°C /
235 kVA @ 40°C /
220 kVA @ 50°C
Rated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:184.0 A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.0%EU efficiency:98.8%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated PID recovery:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1125*770*384 mmWeight:113 kg
Topology:TransformerlessSelf consumption (night):<2 W
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:EN50549, G99,
AS4777.2, VDE0126,
IEC61727, VDE4110,
CEA 2019
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC

Input DCMax. input voltage:1500 VRated voltage:1080 V
Start-up voltage:500 VMPPT voltage range:480-1500 V
Max. input current:14*26 AMax. short circuit current:14*40 A
MPPT number/Max.
input strings number:
14/28
Output ACRated output power:255 kVA @ 30°C /
235 kVA @ 40°C /
220 kVA @ 50°C
Rated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:184.0 A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.0%EU efficiency:98.7%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated PID recovery:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1125*770*384 mmWeight:113 kg
Topology:TransformerlessSelf consumption (night):<2 W
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:EN50549, G99,
AS4777.2, VDE0126,
IEC61727, VDE4110,
CEA 2019
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC

Input DCMax. input voltage:1500 VRated voltage:1080 V
Start-up voltage:500 VMPPT voltage range:480-1500 V
Max. input current:12*30 AMax. short circuit current:12*50 A
MPPT number/Max.
input strings number:
12/24
Output ACRated output power:255 kVA @ 30°C /
235 kVA @ 40°C /
220 kVA @ 50°C
Rated grid voltage:3/PE, 800 V
Rated grid frequency:50 Hz / 60 HzGrid voltage range:640-920 V
Power Factor:>0.99
(0.8 leading - 0.8 lagging)
Max. output current:184.0 A
DC injection current:<0.5% InTHDi:<3%
EfficiencyMax. efficiency:99.0%EU efficiency:98.8%
ProtectionDC reverse-polarity protection:YesShort circuit protection:Yes
Output over current protection:YesSurge protection:DC Type II / AC Type II
Grid monitoring:YesAnti-islanding protection:Yes
Temperature protection:YesStrings monitoring:Yes
I/V Curve scanning:YesNight time SVG function:Yes
Integrated PID recovery:YesIntegrated DC switch:Yes
General DataDimensions (W*H*D):1125*770*384 mmWeight:113 kg
Topology:TransformerlessSelf consumption (night):<2 W
Operating ambient
temperature range:
-25 ~ +60°CRelative humidity:0-100%
Ingress protection:IP66Noise emission (typical):≤65 dB(A)
Cooling concept:Intelligent redundant
fan-cooling
Max. operation altitude:4000 m
Safety/EMC standard:IEC/EN 62109-1/-2,
IEC/EN 61000-6-2/-4
Grid connection standard:EN50549, G99,
AS4777.2, VDE0126,
IEC61727, VDE4110,
CEA 2019
FeaturesDC connection:MC4 connectorAC connection:OT terminal
(max. 300 mm²)
Display:LCDCommunication:RS485, Optional: PLC